ISDN-LNK (ISDN-PRI Signaling Link Port)
Issue 4 May 2002
10-939555-233-123
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2020 ABORT The test did not run due to an already existing error on the
specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the already existing
error.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any FAIL The NPE of the tested port was found to be transmitting in error.
This causes noisy and unreliable connections.
1. Replace the DS1-BD Interface circuit pack.
PASS The port is able to communicate over the TDM Bus.
Table 10-343. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page