ISDN-TRK (DS1 ISDN Trunk)
Issue 4 May 2002
10-989555-233-123
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals
a maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use status
station or status trunk to determine when the port is available
for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1018 ABORT Maintenance is disable on this trunk.
1. Enable maintenance by entering “y” in the “Maintenance
Tests?” field on page 2 of the change trunk-group form.
1117 ABORT A service state audit message is outstanding.
1. Wait two minutes and then try again.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2020 ABORT The test did not run due to an already existing error on the
specific port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the already existing
error.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Any FAIL The NPE of the tested port was found to be transmitting in error.
This will cause noisy and unreliable connections. The
ISDN-TRK is moved to out-of-service/near-end state.
1. Replace the circuit pack.
PASS The port is able to communicate over the TDM Bus.
Table 10-357. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page