Maintenance Object Repair Procedures
555-233-123
10-992 Issue 4 May 2002
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
interface circuit pack to assure that the trunks translation is correct. The port audit
operation verifies the consistency of the current state of trunk kept in the DS1
interface circuit pack and in the switch software.
Table 10-359. TEST #36 Audit and Update Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Internal system error
1018 ABORT Maintenance is disabled on this trunk.
1. Enable maintenance by entering y in the Maintenance
Tests? field on page 2 of the change trunk-group form.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times
FAIL Test failed due to Internal system error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS Trunk translation has been updated successfully. The current
trunk states kept in the DS1 interface circuit pack and switch
software are consistent. If the trunk is busied out, the test will
not run, but will return PASS. To verify that the trunk is
in-service:
1. Enter status-command to verify that the trunk is
in-service. If the trunk is in-service, no further action is
necessary. If the trunk is out-of-service, continue to Step
2.
2. Enter release-trunk to put trunk back into in-service.
3. Retry the test command.
Continued on next page