MODEM-PT (Modem Pool Port)
Issue 4 May 2002
10-1111555-233-123
5006 FIL The Modem Pool Port did not respond to the “maintenance
activate” message. This error is internal to the Modem Pool
circuit pack and does not involve external equipment or
interfaces. The test failed. This error is internal to the Pooled
Modem circuit pack and does not involve external equipment
or interfaces.
1. Busyout both of the TN758 Pooled Modem conversion
resources on the circuit pack containing the failing
conversion resource.
2. If the test continues to fail, replace the Pooled Modem
circuit pack and retest.
3. If the circuit pack fails after replacement, escalate the
problem.
5007 ABORT The Network Control Channel allocated for this test did not
respond to the incoming call indication.
1. Follow the repair procedures for Error Code 5001.
5009 ABORT The Network Control Channel allocated for this test did not
handshake correctly.
1. Attempt the test again.
2. If the same error occurs, test the DATA-CHL circuit pack
using test data-module (refer to the DATA-CHL
maintenance strategy).
3. If the DATA-CHL circuit pack tests pass, escalate the
trouble report.
5010 FAIL The Data Loop Around Test failed, indicating a probable
problem with the TN758 Pooled Modem circuit pack.
1. Follow the repair procedure for Error Code 5006.
5011 ABORT The Network Control Channel allocated for this test did not
disconnect properly.
1. Follow the repair procedures for Error Code 5001.
5012 ABORT The digital portion of the tested Modem Pool Port did not
disconnect properly.
1. Follow the repair procedures for Error Code 5000.
Table 10-417. TEST #98 Modem Pool Conversion Resource Loop Around Test
— Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page