MMI-BD
Issue 4 May 2002
10-1123555-233-123
Control Channel Looparound Test (#52)
Refer to the repair procedure described in the XXX-BD (Common Port Circuit
Pack) maintenance documentation as Control Channel Looparound Test (#52).
SAKI Sanity Test (#53)
Refer to the repair procedure described in the XXX-BD (Common Port Circuit
Pack) maintenance documentation as SAKI Sanity Test (#53).
Table 10-423. TEST #1122/1123 MMI Synchronization Status Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Internal system error. This is an abnormal abort.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2000 ABORT A response to the test was not received from the MMI circuit pack
within the allowable time period.
1. If this result occurs repeatedly and the MMI circuit pack is
idle, reset the circuit pack using busyout board PCSS, then
reset board PCSS, followed by release board PCSS.
2. Rerun the test; if the same result occurs again, replace the
MMI circuit pack.
2012 ABORT Internal system error
2100 ABORT Could not allocate the necessary resources to run this test. This
is an abnormal abort.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL The MMI circuit pack is out of MMI synchronization. Run the long
option of the test board command.
1. Wait up to 5 minutes, and then reset the circuit pack with
these commands: busyout board PCSS, then reset board
PCSS, followed by release board PCSS.
2. Rerun the test; if the same result occurs again, replace the
circuit pack.
1100 PASS The MMI circuit pack is providing the synchronization correctly.
This MMI circuit pack is designated as the Master Sync source.
1101 PASS The MMI circuit pack is listening to the synchronization signal
correctly.
Continued on next page