M/T-ANL (Maintenance/Test Analog Port)
Issue 4 May 2002
10-1135555-233-123
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. This error code appears in the Error Log only if the MTB circuit pack has
been removed since the Error Log was last cleared. Verify that the circuit
pack has been reinserted.
b. This error indicates a hardware failure on the Analog Port circuitry. Replace
the Maintenance/Test circuit pack if the alarm is not resolved by the
command above.
c. This error indicates that call processing records did not agree with
on-board records for the hook state (on-/off-hook) of the Maintenance/Test
Analog Port. This error is not service-affecting and no action is required.
M/T-ANL Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
(a)
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp
1 (b) 41018 none MINOR ON test port PCSSpp l r 3
18 0 busyout port PCSSpp WARNING OFF release port PCSSpp
257 Any NPE Crosstalk test (#9) MINOR ON test port PCSSpp l r 3
513 Any Analog Port Sanity Test
(#963)
MINOR ON test port PCSS01 r 2
769 Any Analog Port Digital Loop
Around Test (#13)
MINOR ON test port PCSSpp r 3
3840(c) Any Hook State Inquiry test
(#566)