M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286,
G3iV2-386]
Issue 4 May 2002
10-1149555-233-123
Table 10-433. TEST #9 NPE Cross Talk Test
Error
Code
Tes t
Result Description/Recommendation
1000 ABORT System resources required to run this test are not
available. The port may be in use on a valid ISDN-PRI test
call. Use the list isdn-testcall command to determine if the
port is in use (if the port is listed in the M/T Port column). If
it is in use, either wait for the test call to complete (as
indicated in the Start Time and Duration fields in the above
display), or abort the test call with the clear isdn-testcall
tg/mem command, where tg/mem is determined from the
B-channel field of the above display.
1. Retry the command at one-minute intervals a
maximum of 5 times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1001 ABORT System resources required to run this test are not
available.
1. Retry the command at one-minute intervals a
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may
have time slots out of service due to TDM-BUS errors.
Refer to TDM-BUS Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at one-minute intervals a
maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test.
The system may be oversized for the number of tone
detectors present or some tone detectors may be
out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present,
refer to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present,
refer to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at one-minute
intervals a maximum of 5 times.
Continued on next page