Maintenance Object Repair Procedures
555-233-123
10-1156 Issue 4 May 2002
1138 ABORT This test does not run on Port 3 of the Maintenance/Test
circuit pack. This test runs only on Port 2. Look at the
results of the Digital Port Sanity Test for Port 2.
1. Run the command again for Port 2 via the test port
PCSS02 or test port PCSS02 l command.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required to run this test are not
available.
2500 ABORT An internal operation failed; the test could not be
completed.
1. Retry the command at one-minute intervals a
maximum of 5 times.
50 FAIL The switch was unable to communicate with the port
circuitry used for digital trunk testing.
100 FAIL Data was not sent from Port 2 to Port 3 successfully in
asynchronous mode.
101 FAIL Data was not sent from Port 3 to Port 2 successfully in
asynchronous mode.
102 FAIL Data was not sent from Port 2 to Port 3 successfully in
synchronous mode.
103 FAIL Data was not sent from Port 3 to Port 2 successfully in
synchronous mode.
1. Reset the circuit pack via the busyout board PCSS,
reset board PCSS, release board PCSS command
sequence.
2. Test the port again via the test port PCSS02 l
command.
3. If the test fails again, replace the circuit pack.
PASS The Maintenance/Test Digital Port digital trunk testing
capability is operating correctly.
Table 10-436. TEST #565 Digital Port SanityTest — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page