M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286,
G3iV2-386]
Issue 4 May 2002
10-1155555-233-123
Table 10-436. TEST #565 Digital Port SanityTest
Error
Code
Te s t
Result Description/Recommendation
1000 ABORT One of the Maintenance/Test Digital Ports is busy with
background maintenance.
1. Either wait for the port to become idle, or busyout both
Maintenance/Test Digital Ports on the
Maintenance/Test circuit pack via busyout port
PCSS02 and busyout port PCSS03, respectively.
2. Release the ports (if they were busied out) via release
port PCSS02 and release port PCSS03, respectively.
3. Retry the command at one-minute intervals a
maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions, or it may
have time slots out-of-service due to TDM-BUS errors.
Refer to the TDM-BUS Maintenance documentation to
diagnose any active TDM Bus errors.
1. If the system has no TDM-BUS errors, and if not
handling heavy traffic, repeat the test at one-minute
intervals a maximum of 5 times.
1004 ABORT The port was seized by a valid ISDN-PRI Test Call. Use the
list isdn-testcall command to determine which call is using
the port (from the M/T Port column). Either wait for the test
call to complete (as indicated in the Start Time and
Duration fields of the above display), or abort the test call
with clear isdn-testcall tg/mem, where tg/mem is
determined from the B-channel field of the above display.
1019 ABORT An ISDN Test Call is in progress using this
Maintenance/Test circuit pack. The Maintenance/Test
circuit pack cannot perform a self-test on one of its Digital
Ports while an ISDN Test Call is using either of the Digital
Ports. Use list isdn-testcall to determine which call is
using the port (form the M/T Port column). Either wait for
the test call to complete (as indicated in the Start Time and
Duration fields of the above display), or abort the test call
with clear isdn-testcall tg/mem, where tg/mem is
determined from the B-channel field of the above display.
1. Retry the command at one-minute intervals a
maximum of 5 times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
Continued on next page