Maintenance Object Repair Procedures
555-233-123
10-1164 Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1
This error indicates that the system is in the Serial Number
Mismatch state, and in addition that a License Error failure has occurred
(See MO LIC-ERR Error Type 1). This error is caused by a serial number
mismatch, and the expiration of the six day timer for the processor located
in carrier A of a duplicated G3si. Call processing will be restricted to
outgoing calls to emergency numbers, and incoming calls to an
Administration number.
b. Error Type 257
This error indicates that the system is in the Serial
Number Mismatch state, and in addition that a License Error failure has
occurred (See MO LIC-ERR Error Type 257). This error is caused by a
serial number mismatch, and the expiration of the six day timer for the
processor located in carrier B of a duplicated G3si. Call processing will be
restricted to outgoing calls to emergency numbers, and incoming calls to
an Administration number.
c. Error Type 513
This error indicates that the license has expired, and in
addition that a License Error failure has occurred (See MO LIC-ERR Error
Type 513) and the six day timer has expired. Call processing will be
restricted to outgoing calls to emergency numbers, and incoming calls to
an Administration number.
Table 10-440. NO-LIC Error Log Entries
Error
Type
Aux
Data
Associated
Test Alarm Level
On/Off
Board Test to Clear Value
1(a) MAJOR OFF See Footnote
1
1 Clear this Error Type by providing the correct License File per local instructions.
257(b) None MAJOR OFF See Footnote
1
513(c) None MAJOR OFF See Footnote
1
769(d) None MAJOR OFF See Footnote
1
1025(e) None MAJOR OFF See Footnote
1
1281(f) None MAJOR OFF See Footnote
1
1537(g) None MAJOR OFF See Footnote
1
1793(h) None MAJOR OFF See Footnote
1
2049(i) None MAJOR OFF See Footnote
1
2305(j) None MAJOR OFF See Footnote
1
2561(k) None MAJOR OFF See Footnote
1
2817(l) None MAJOR OFF See Footnote
1