PDMODULE, TDMODULE (Data Module)
Issue 4 May 2002
10-1197555-233-123
3 ABORT No response from EPF audit.
4 ABORT Internal System Error.
1. Resolve any outstanding circuit pack maintenance
problems.
2. Retry the command at one-minute intervals a maximum of 5
times.
5 ABORT Ringer update aborted (data module not in the in-service state).
1. Verify that the data module is powered (power LED on).
2. Make sure data module is connected to the building wiring,
check for faulty wiring, check for faulty data module.
3. Retry the command at one-minute intervals a maximum of 5
times.
4. Replace the Data Module and repeat the test.
5. If the test continues to abort, replace the Digital Line circuit
pack and repeat the test.
6 ABORT Data module translation update aborted.
1. Verify the data module is connected to the PBX.
2. Retry the command at one-minute intervals a maximum of 5
times.
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to the test request was not received within the
allowable time period.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a maximum of 5
times.
PASS Data Module Audits passed. This digital port circuit pack is
functioning properly.
1. If complaints still exist, investigate by using other port tests,
and by examining the data module options, wiring, and
connections.
Table 10-447. TEST #17 Data Module Audits Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page