PI-BD (Processor Interface Circuit Pack)
Issue 4 May 2002
10-1225555-233-123
!
WARNING:
The “test interface long” command resets the PI-BD and cause all ISDN-PRI
and BX.25 links to come down.
Notes:
a. Indicates the circuit pack totally stopped functioning or it was physically
removed from the system.
NOTE:
The alarm is logged about 11 minutes after the circuit pack has been
removed and/or SAKI Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack (in the same slot
as the error indicates) to resolve this error. Or, if the circuit pack is in the
system and the red LED is on, then replace the circuit pack.
!
CAUTION:
Reseating the circuit pack may cause a system restart if the circuit
pack is located on an Active SPE complex.
If this is a Duplicated Option system, verify that there is an equal number of
Processor Interface circuit packs in each SPE complex. If there is not an
equal number of Processor Interface circuit packs, this condition could
cause alarms on the STBY-SPE, DUPINT, SHDW-CIR, as well as the
PI-BD.
1025 (i) 4363 NPE Audit Test (#50) test interface PCS sh
1538 (j) Any None MINOR ON
3585 (d) Any None Test (#423) MAJOR ON reset interface PCS l
3840 (i) Any None
3841 Any Standby PI Circuit Pack
Test (#423)
MAJOR ON test interface PCS sh
3999(k) Any None
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-458. PI-BD Error Log Entries — Continued
Error
Code
Aux
Data Associated Test
Alarm
Level
On/
Off
Board Test to Clear Value
Continued on next page