Maintenance Object Repair Procedures
555-233-123
10-1246 Issue 4 May 2002
16387 FAIL Excessive Level 2 resets and excessive Level 2 I-frame
retransmission.
16389 FAIL Excessive Level 2 resets and excessive LAPD invalid frame
errors.
16390 FAIL Excessive Level 2 I-frame retransmissions and excessive LAPD
invalid frame errors.
16391 FAIL Excessive Level 2 I-frame retransmissions, excessive LAPD
invalid frame errors, and excessive Level 2 resets.
1. See PI-LINK ( Processor Interface Link) Maintenance
documentation for this maintenance object.
16392 FAIL HDLC receive rate exceeded the threshold.
16400 FAIL HDLC transmit rate exceeded the threshold.
16393-
16425
FAIL Other combinations of above individual failures can be calculated
as follows:
16384 = 0X4000
16385 = 0X4001
16386 = 0X4002
16388 = 0X4004
16316 = 0X4010
PASS PI-LINK currently does not have any of the above errors.
Table 10-463. TEST #233 Link Quality Test — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page