PKT-CTRL (Packet Control Circuit Pack)
Issue 4 May 2002
10-1287555-233-123
2500 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1-3 FAIL The reset test failed.
1. Retry the command.
2. If it fails again with the same error code, replace the
Packet Control circuit pack.
5 FAIL The SPE could not communicate with the Packet Control
circuit pack. This indicates that either the Packet Control circuit
pack is not installed or that it has failed.
1. Examine the appropriate carrier to determine if there is a
Packet Control circuit pack in the correct slot. If there is,
go to the next step. If there isnt, the problem is that the
Packet Control circuit pack is administered (that is, the
Packet Bus Activated? field on the Maintenance-Related
System Parameters Form is set to y) but the circuit pack
isnt installed. If the system is supposed to have a Packet
Control circuit pack, the system must be upgraded
appropriately (see upgrade documentation). If the system
is not supposed to have a Packet Control circuit pack,
then the Packet Control circuit pack should be
unadministered by setting the Packet Bus Activated?
field on the Maintenance-Related System Parameters
Form to n. Refer to the Maintenance-Related System
Parameters Form section in Chapter 5, ‘‘Routine
Maintenance Procedures’’ for more information on the
Packet Bus Activated? field.
2. Retry the command.
3. If it fails again with the same error code, replace the
Packet Control circuit pack.
Table 10-482. TEST #586 Packet Control Reset Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page