PKT-INT (Packet Interface)
Issue 4 May 2002
10-1309555-233-123
2 FAIL The Private Level 2 looparound test failed. The Packet Interface
will enter a fatal fault state when this occurs and the Packet
Interface Maintenance software should put the Packet Interface
in a out-of-service state. Therefore by the time further action is
taken, it is expected that the test will abort with ABORT code
1137 and a demand reset should be used to test the circuit pack.
1. Reset the Packet Interface using the reset
packet-interface CS command. Refer to the repair
procedures for the Packet Interface Reset Test (#889) for
further action.
2. If the test continues to fail, replace the TN2401/TN794
NetPkt circuit pack.
3 FAIL The Private Link Level 3 looparound test failed. The Packet
Interface may still be operational.
1. Retry the command.
2. If the test continues to fail with the same error code:
a. If the system is not equipped with the High Reliability or
Critical Reliability Configuration replace the
TN2401/TN794 NetPkt circuit pack.
b. If the system is equipped with the High Reliability or
Critical Reliability Configuration and if the Packet
Interface is on the standby SPE, replace the
TN2401/TN794 NetPkt circuit pack on the standby SPE.
c. If the system is equipped with the High Reliability or
Critical Reliability Configuration and if the Packet
Interface is on the active SPE,
3. Perform a planned SPE interchange by entering the
command reset system interchange, and retry the test
command.
4. If the test of the Packet Interface on the standby SPE
continues to fail, replace the standby TN2401/TN794 NetPkt
circuit pack.
Table 10-485. TEST #885 Private Looparound Tests Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page