EasyManua.ls Logo

Avaya Definity SI - Page 2100

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Object Repair Procedures
555-233-123
10-1314 Issue 4 May 2002
1339 ABORT The test could not run on the standby Packet Interface because
the standby SPE is unavailable.
1. Refer to the STBY-SPE maintenance documentation for
information on why a standby SPE may be unavailable and
what repair actions should be taken. The status syst
1screen indicates the state of the standby SPE.
Unavailability may be caused by a variety of reasons, such
as the setting the SPE-SELECT switches on the DUPINT
circuit packs to the position of the active SPE, a failure of the
DUPINT circuit pack, or loss of power on the standby SPE.
The SPE Select Switch field on the status syst 1 screen
will display spe a or spe b if the SPE-SELECT switches are
in the a or b position, respectively.
2000 ABORT Response to the test request was not received within the
allowable time period. Retry the command at 1-minute intervals, a
maximum of 3 times.
2500 ABORT Internal system error
1. Retry the command.
NO
BOARD
The Packet Interface is not detected as being physically present.
1. Reboot the system, then retry the command. If the NO
BOARD indication persists, replace the TN2401/TN794
NetPkt circuit pack.
Table 10-487. TEST #887 Read and Clear Board Counters Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page