PMS-PRNT/JNL-PRNT (PMS Printer Link)
Issue 4 May 2002
10-1335555-233-123
Link Tear Down Test (#213)
This test is destructive.
This test disconnects the existing link between the system and the external printer
device. If the link has been disconnected already, this test just returns PASS. All
resources allocated for a PMS Printer Link are released after this test.
Table 10-493. TEST #213 Link Tear Down Test
Error
Code
Te s t
Result Description/Recommendation
40 ABORT Internal system error
50 ABORT Internal system error
1. Retry the command at 1minute intervals a maximum of 5
times.
1010 ABORT The link has been busied out to out-of-service.
1. Enter release journal wakeup-log|pms-log command
to release the link from busyout state.
2. Retry test journal wakeup-log|pms-log l command to
execute the test.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS The link is torn down.
Continued on next page