POWER (Battery & Battery Charger) for AC-Powered
Systems
Issue 4 May 2002
10-1347555-233-123
14 FAIL This indicates that Error Codes 2, 4, and 8 have occurred. Refer to
these descriptions.
NOTE:
This could also indicate that the detection logic on the
DUPINT (Duplication Interface), PR-MAINT
(Maintenance/Tape Processor), or EPN MAINT
(Maintenance) circuit pack is defective. Such an error will
not be detected by the respective maintenance. If many
environment tests are failing, replace the suspect circuit
pack (depending on system configuration).
PASS The Maintenance/Tape Processor in a multicarrier cabinet PPN
system without High or Critical Reliability, the Duplication Interface
circuit pack in a PPN for a High or Critical Reliability system, or the
EPN Maintenance circuit pack in an EPN have reported that the
status of Battery & Battery Charger is good.
Table 10-495. TEST #5 Battery & Battery Charger Query Test Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page