Maintenance Object Repair Procedures
555-233-123
10-1356 Issue 4 May 2002
Test failure indicates failure of the
■ CLAN (TN799) circuit pack
■ TDM Bus
■ Tone generator / tone receiver circuit pack
Table 10-500. TEST #1285 TDM Looparound Test
Error
Code
Tes t
Result Description/Recommendation
1000 ABORT The port is in use.
1. Determine port status (status clan-port UUCSSpp).
2. Retry the command when the port is idle. The port may be
forced to the idle state by executing a busyout port UUCSS
command.
3. Escalate if the problem persists.
NOTE:
The busyout port command is destructive, causing all
calls and links associated with the port to be torn down.
1002 ABORT No TDM bus timeslots available for the test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
1003 ABORT No more tone receivers idle for use in this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2000 ABORT Did not receive circuit pack test response within the allowable
time period.
1. If this problem persists, reset the circuit pack (busyout
board UUCSS, reset board UUCSS, and release board
UUCSS).
2. If the problem persists, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
Continued on next page