Maintenance Object Repair Procedures
555-233-123
10-1382 Issue 4 May 2002
Table 10-513. TEST #230 External Modem Present Test
Error Code
Te s t
Result Description/Recommendation
100 ABORT The test did not complete within the allowable time period.
1. Retry the command.
1018 ABORT The test has been disabled via administration.
1. To enable the test, issue the change
system-parameters maintenance command, and set
the Test Remote Access Port field to “y.”
2. Rerun the test.
1030 ABORT This test is not run on the Standby SPE.
1131 ABORT INADS port is busy because the system is reporting alarms
to INADS, or because INADS is dialed into the system.
1. If INADS is communicating with the switch the INADS
trunk is working. There is no need to run this test.
2. Or if required. Wait about ten minutes (until the INADS
session is terminated) and then re-enter the command.
1000 ABORT System software resources required for this test are not
available.
2033 Internal system error
1. Retry at 1-minute intervals a maximum of 5 times.
1049 ABORT External Modem is not administered.
1050 ABORT System could not determine if the testing of the INADS port
is administered.
1. Enter the change system-parameters maintenance
command, and verify the entry for the Test Remote
Access Port field.
2. Retry at 1-minute intervals a maximum of 5 times.
2000 ABORT MTP did not respond to the test request.
1. Repeat test at 1-minute intervals a maximum of 5 times.
2. If all MTP tests are aborting, execute the test
processor a/b long command in order to reset MTP,
and examine the results of the MTP Reset Test (#101).
2500 ABORT Internal System software Error
1. Retry at 1-minute intervals a maximum of 5 times.
Continued on next page