EasyManua.ls Logo

Avaya Definity SI - Page 2181

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PR-MAINT (Maintenance Processor)
Issue 4 May 2002
10-1395555-233-123
Table 10-518. TEST #104 MTP Dual Port Ram Test
Error
Code
Te s t
Result Description/Recommendation
1029
2014
2015
2016
2017
2018
2020
2022
2024
2025
2051
ABORT (Refer to STBY-SPE Maintenance documentation for a
description of these error codes.)
1000 ABORT System software resources required to run this test are not
available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1030 ABORT The component on which the test was to be run is on the
Standby SPE. This test may be run on this component only
when it resides on the Active SPE.
1. For a recommended maintenance procedure, refer to
ABORT Error Code 1030 in STBY-SPE Maintenance
documentation.
2000 ABORT Response to the test request was not received within the
allowable time period.
2028 ABORT System software resources required for this test are not
available.
2029 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL The dual port RAM is not functioning correctly.
Communication between the processor and MTP is lost. The
system is not able to report environmental alarms,
communicate with the Standby SPE, or reboot from tape, if
necessary.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to fail, replace the Processor circuit
pack.
PASS Dual port RAM is functioning. Communication exists between
the 80286/386 Processor circuit pack and the MTP.
Continued on next page

Table of Contents

Related product manuals