Maintenance Object Repair Procedures
555-233-123
10-1418 Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. The Software Initiated Interrupt Test (#77) failed. Refer to the FAIL
condition of this test for further action.
b. The ROM Checksum Test (#80) failed. Refer to the FAIL condition of this
test for further action.
c. The Processor Non-maskable Interrupt Test (#82) failed. Refer to the FAIL
condition of this test for further action.
d. The Processor Sanity Timer Test (#83) failed. Refer to the FAIL condition of
this test for further action.
Table 10-532. 80286/386 Processor Circuit Pack Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/
Off
Board Test to Clear Value
1
1 Software does not accept the repeat option on the TN773 circuit pack [G3iV1.1-286]. The repeat
option is valid only on the TN786B circuit pack. You must manually repeat the command with the
long option the designated number of times from the administration terminal and from a remote SAT
because the Sanity Timer Test (#83) logs you off. In G3iV1.1-286, if the test processor long
System Technician command is executed six times back-to-back, the system goes into
SPE-DOWN mode.
0
2
2 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test processor a/b r 1
1 (a) 0 Software Initiated Interrupt
Test (#77)
MAJOR ON test processor a/b r 3
769 (b) 0 ROM Checksum Test (#80) MAJOR ON test processor a/b r 5
1025 (c) 0 Processor Non-maskable
Interrupt Test (#82)
MAJOR ON test processor a/b r 2
1281 (d) 0 Processor Sanity Timer Test
(#83)
MAJOR ON test processor a/b l r 2