Maintenance Object Repair Procedures
555-233-123
10-1448 Issue 4 May 2002
Status of Parameter Downloads
The status station and status attendant screens display the current download
status of individual 84xx, 603, and 301B1 terminals in the Download Status
field. The possible download states are:
Possible reasons for no terminal download include:
■ Terminal is off-hook
■ Terminal detected a bad checksum
■ Terminal detected a bad or missing EEPROM (refer to hardware error log)
■ Terminal is busy programming data from a previous PROGRAM message
■ Terminal is in the Programming Disabled state
■ Terminal is in the Local Program Options Mode
■ Terminal is disconnected or out of service (use status station command)
Status Terminal Download State
Complete The terminal successfully downloaded sometime in the past.
Pending The system is waiting to download the terminal. This may require
the execution of a background periodic test which could take more
than an hour. A demand download as described above may also be
used to initiate an immediate download.
Not Applicable Not a programmable terminal.
Table 10-549. Digital Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 1 to 20,
40987
None WARNING OFF
18 (b) 0 busyout port
UUCSSpp
WARNING OFF re port UUCSSpp
257 (c) 40971 None
513 (d) 0 Station (Digital)
Audits Test (#17)
WARNING OFF test port UUCSSpp sh r 6
767 (e) 40964 None WARNING OFF
769 (f) 40963
40988
None WARNING OFF
1025 (g) None WARNING OFF
1281 Any Station (Digital)
Audits Test (#17)
WARNING OFF test port UUCSSpp sh r 4
Continued on next page