RDIG-STA (Remote Digital Station)
Issue 4 May 2002
10-1453555-233-123
DIG-LINE Station Lamp Updates Test (#16)
This test lights all lamps on the terminal as specified. The lamp updates will run
only if the station is in-service. The status of the station is checked and the lamp
updates are blocked from taking place, if the station is not in the in-service state.
This test does not affect the status of the Message Waiting lamp.
Table 10-551. TEST #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result Description/Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum
of 5 times.
1 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied
out) for this port. If this error type is present, then
release the port using the release station extension
command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum
of 5 times.
3 ABORT Station may be in ready-for-service or out-of-service state.
1. Use the status station command to verify the state of
the station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum
of 5 times.
1000 ABORT System resources required to run this test are not available. The
port may be busy with a valid call. Use display port UUCSSpp
to determine the station extension or attendant number of the
port. Use status station or status attendant to determine the
service state of the port. If the port is in use, wait until the port is
idle before testing. Attendants are always in use (off-hook) if the
handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
Continued on next page