Maintenance Object Repair Procedures
555-233-123
10-1474 Issue 4 May 2002
Table 10-557. TEST #7 Conference Circuit Test
Error
Code
Tes t
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of 5
times.
1000 ABORT System resources required to run this test are not available. The
port may be busy with a valid call and therefore unavailable for
certain tests. You must wait until the port is idle (yellow LED if off)
before retesting.
1. If the port is idle, retry the command at one-minute intervals a
maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test and the test has
been aborted. You must wait until the port is idle (yellow LED if off)
before retesting.
1. Retry the command at one-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use, escalate
the problem.
1020 ABORT The test did not run due to an already existing error on the specific
port or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the
circuit pack and attempt to diagnose the already existing error.
2000 ABORT Response to the test request was not received within the allowable
time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of 5
times.
Any FAIL The NPE of the tested port did not conference the tones correctly.
This causes noisy and unreliable connections.
1. Retry the test.
2. If the Test continues to fail then replace the circuit pack.
PASS The port can correctly conference multiple connections.
User-reported troubles on this port should be investigated using
other port tests and examining the Error Log.
Continued on next page