S-SYN-PT (Speech Synthesis Port)
Issue 4 May 2002
10-1477555-233-123
Table 10-560. TEST #165 Speech Synthesis DSP Tone Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of 5
times.
1000 ABORT System resources required to run this test are not available. The
port may be busy with a valid call and therefore unavailable for
certain tests. You must wait until the port is idle (yellow LED if off)
before retesting.
1. If the port is idle retry the command at one-minute intervals a
maximum of 5 times.
1001
1002
1003
ABORT System resources required to run this test are not available.
1. Retry the command at one-minute intervals a maximum of 5
times.
1021 ABORT The 440-Hz tone was not detected by the Tone Detector circuit
and inter-digit time-out has occurred on the Tone Detector circuit.
1. Retry the command at one-minute intervals a maximum of 5
times.
2. If the test continues to abort, verify all Tone Detector circuit
packs in the system are functioning correctly by checking the
Error Log and using the test board PCSS long command.
Replace any faulty Tone Detector circuit packs and repeat the
test.
3. If the test continues to abort, replace the Speech Synthesis
circuit pack.