Maintenance Object Repair Procedures
555-233-123
10-1488 Issue 4 May 2002
Table 10-568. TEST #284 Common Shadow Circuit Address Decoder Test
Error Code
Tes t
Result Description/Recommendation
1029 1030
2011 2012
2013 2014
2015 2016
2017 2018
2019 2020
2021 2022
2023 2024
2025 2051
ABORT Refer to the STBY-SPE Maintenance documentation for a
description of these error codes.
ABORT Internal system error
1022 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of
5 times.
FAIL The Common Shadow Circuit portion of the Duplication
Interface circuit pack is defective and the Duplication
Interface circuit pack must be replaced.
1. Follow the “Repair Procedures for High and Critical
Reliability” in Chapter 6, ‘‘Reliability Systems: A
Maintenance Aid’’ and replace the Duplication Interface
circuit pack.
2. Rerun the test.
NO
BOARD
The Duplication Interface circuit pack has failed to
handshake with either the active Maintenance/Tape
Processor (in the case of Duplication Interface circuit pack A)
or the Duplication Interface circuit pack A (in the case of
Duplication Interface circuit pack B).
1. Refer to NO BOARD description for the Duplication
Interface Circuit Pack Status Query Test (#315) in
DUPINT Maintenance documentation.
PASS Part of the Common Shadow Circuit is operating properly;
however, Tests #283 and #285 must pass before the
Common Shadow Circuit on this Duplication Interface circuit
pack is considered sane.
Continued on next page