SPE-SELEC (SPE Select Switch)
Issue 4 May 2002
10-1515555-233-123
Table 10-575. TEST #278 SPE Select Query Test
Error
Code
Te s t
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
2000 ABORT Response to the test request was not received within the
allowable time period.
2033 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1 FAIL The switch currently selects SPE-A active.
2 FAIL The switch currently selects SPE-B active.
1. Move the switch to the AUTO position.
2. Rerun the test.
3 FAIL The Duplication Interface circuit pack is not present or not
functioning.
1. Resolve all alarms logged against the Duplication Interface
circuit pack (DUPINT).
2. Rerun the test.
PASS The Duplication Interface circuit pack has reported that the SPE
Select Switch is in the AUTO position.
1. If a visual inspection shows the SPE Select Switch is not in
the AUTO position, then resolve all alarms logged against
Duplication Interface circuit pack (DUPINT).
2. Repeat the test.
3. If Duplication Interface circuit pack B is being tested and a
visual inspection shows that the switch is not in the normal
position, Duplication Interface circuit pack A may be
incorrectly reporting the state of SPE-Select Switch B.
Replace Duplication Interface circuit pack A, and rerun the
test.
Continued on next page