1030 ABORT The component on which the test was to be run is on the Standby
SPE. This test may only be run on this component when it resides
on the Active SPE. If it is absolutely necessary to conduct this test
on the Standby SPE component, implement the following steps to
make it become an Active SPE component.
1. Issue refresh spe-standby to return the Standby SPE to
Standby Mode. This command may have to be issued multiple
times. If refresh spe-standby successfully completes 5 times
without the Standby SPE becoming labeled standby on the
status system form, wait 20 minutes. This does not include
cases where the command completes with the terminal
message line errors Refresh not successful; use display
errors to check for STBY-SPE errors or Cannot interrupt
Standby SPE while entering maintenance mode; please try
later. Issue refresh spe-standby once more.
2. Issue reset system interchange in order to cause an SPE
switch. At this point, the component resides on the Active SPE.
1030
(contd.)
ABORT 3. Move the SPE Select switches to make the SPE with the
problem the current Active SPE. This action prevents software
from switching to the other SPE since the current SPE has the
error against it.
4. Repeat the test.
5. If the test passes and the alarm is resolved, return the SPE
Select switches to the AUTO position.
6. If the test fails and the defective circuit pack is identified, the
circuit pack needs to be replaced. However, the circuit pack now
resides on the current Active SPE. Return the SPE Select
switches to the AUTO position. Issue refresh spe-standby and
then execute reset system interchange to cause an SPE
switch.
7. The system is now on the healthy SPE. Replace the defective
circuit pack on the Standby SPE as previously identified in Step
4. Refer to the Replacing Defective SPE Circuit Packs section
in Chapter 6, ‘‘Reliability Systems: A Maintenance Aid’’.
8. Repeat the procedure, beginning with Step 1.
2011
2012
2013
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
Table 10-578. Test Result Error Codes Associated with the Standby SPE Continued