Maintenance Object Repair Procedures
555-233-123
10-1570 Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
Notes:
a. This error type indicates that a circuit pack type other than one of the
following types was inserted into slot 00 (SERVICE slot) of the J58890BB
port carrier.
■ Call Classifier (TN744)
■ Integrated Announcement (TN750)
■ Maintenance/Test (TN771C)
■ Speech Synthesizer (TN725B)
■ Tone Detector (TN748C)
The code of the invalid circuit pack can be displayed by using the list
configuration board UUCSS command, where “UU” is the universal
cabinet number, “C” is the carrier number, and “SS” is the slot number
(always 00) of the alarmed circuit pack.
Remove the invalid circuit pack to retire the alarm.
Service Slot Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
600 (a) None MINOR ON