EasyManua.ls Logo

Avaya Definity SI - Page 2358

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Object Repair Procedures
555-233-123
10-1572 Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error may not cause a Switch Control alarm if Error Type 769 is also
present since this error may actually be caused by the loss of clock signals
and not by a Switch Control failure.
Table 10-581. SW-CTL Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test network-control a/b sh r 1
1 Any Control Channel
Test (#94)
MAJOR ON test network-control a/b r 3
2 (a) Control Channel
Test (#94)
MAJOR ON test network control a/b r 3
257 (b) 0
1
None
513 (c) Time of Day Clock
Test (#95)
MINOR ON test network-control a/b l r 3
769 (d) Any None
1025 Switch Control
Loop Around Test
(#92)
MAJOR ON test network-control a/b r 3
1281
(e)
Any None
1537 Switch Control
Reset Test #93
MAJOR ON test network-control a/b l r 2
1793 (f) Any None
2817 MCD Loop Around
Test (#324)
MAJOR ON test network-control a/b r 2
3073 MCD Memory Test
(#325)
MAJOR ON test network-control a/b r 3
3329
(g)
None MAJOR ON
Continued on next page