Maintenance Object Repair Procedures
555-233-123
10-1572 Issue 4 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. This error may not cause a Switch Control alarm if Error Type 769 is also
present since this error may actually be caused by the loss of clock signals
and not by a Switch Control failure.
Table 10-581. SW-CTL Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test network-control a/b sh r 1
1 Any Control Channel
Test (#94)
MAJOR ON test network-control a/b r 3
2 (a) Control Channel
Test (#94)
MAJOR ON test network control a/b r 3
257 (b) 0
1
None
513 (c) Time of Day Clock
Test (#95)
MINOR ON test network-control a/b l r 3
769 (d) Any None
1025 Switch Control
Loop Around Test
(#92)
MAJOR ON test network-control a/b r 3
1281
(e)
Any None
1537 Switch Control
Reset Test #93
MAJOR ON test network-control a/b l r 2
1793 (f) Any None
2817 MCD Loop Around
Test (#324)
MAJOR ON test network-control a/b r 2
3073 MCD Memory Test
(#325)
MAJOR ON test network-control a/b r 3
3329
(g)
None MAJOR ON
Continued on next page