SYNC (Synchronization)
Issue 4 May 2002
10-1597 555-233-123
Test Synchronization Test (#417)
This test updates all the Synchronization Maintenance component circuit packs
with the correct information regarding their role in providing synchronization for
the system. All the Tone-Clock, Expansion Interface, and DS1 Interface circuit
packs in the system are updated via this test. This test will either pass or abort.
Table 10-589. TEST #417 Test Synchronization Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS The Synchronization Maintenance component circuit pack
parameters have been successfully updated. The system
should be synchronized after successful execution of this test.
If synchronization problems still exist, refer to the Error Log to
obtain information regarding the source of the problem.
Continued on next page