SYS-PRNT (System Printer)
Issue 4 May 2002
10-1605 555-233-123
4. If four data channels are administered and none are available, then look for
DATA-CHL/DATA-CON/DATA-BD errors in the Hardware Error Log. If
errors are present, refer to these MO sections for recommended
maintenance strategy. When problems (if any) with
DATA-CHL/DATA-CON/DATA-BD have been resolved, continue with Step
5.
If fewer than four data channels are administered, then use the add
data-module command to add a network control data module to the
system.
5. Verify the availability of the external SYS-PRNT output device as follows:
Make sure that the SYS-PRNT output device is on-line and
ready-for-service. Check the physical connectivity between the Data
Module and the SYS-PRNT output device or between the EIA port on the
backplane of the switch and the SYS-PRNT output device.
6. Verify that there are less than three active logins to the system. If this
condition exists, a login session must be terminated before the System
Printer Link can be established.
NOTE:
It is recommended that the System Printer Link be busied out before
executing maintenance tests over objects which compose the
System Printer Link. If the System Printer Link is busied out, then all
System Printer Link maintenance actions are deactivated.
Error Log Entries and Test to Clear Values
Table 10-592. SYS-PRNT Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test sp-link
18 (a) 0 busyout sp-link WARNING OFF release sp-link
257 (b) 1 to 6 Link Retry Test
(#215)
MINOR/
WARNING
2
2 Minor alarms on this MO may be downgraded to Warning alarms based on the value in set options.
OFF test sp-link l
513 (c) 0 None MINOR OFF test sp-link