SYS-PRNT (System Printer)
Issue 4 May 2002
10-1607 555-233-123
System Technician-Demanded Tests: Descriptions
and Error Codes
When inspecting errors in the system and deciding which ones to address, always
investigate errors in the order they are presented in the table below. By clearing
error codes associated with the Link Retry Test, for example, you may also clear
errors generated from other tests in the testing sequence.
Link Tear Down Test (#213)
This test is destructive.
The Link Tear Down Test disconnects the existing link between DEFINITY
Generic 1 and the external SYS-PRNT output device. If the link has been
disconnected already, this test just returns PASS. All resources allocated for a
System Printer Link are released after this test.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive; ND = Nondestructive
Link Tear Down Test (#213) X D
Link Retry Test (#215) X X ND
Link Tear Down Test (#213) X X ND
Table 10-593. TEST #213 Link Tear Down Test
Error
Code
Te s t
Result Description/Recommendation
40, 50 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 2
times.
1010 ABORT The System Printer Link has been busied out.
1. Enter release sp-link to release the System Printer Link
from the busyout state.
2. Reissue test sp-link long to execute the test.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 2
times.
PASS The System Printer Link is torn down or a Short Test
Sequence was executed and the link was not torn down.
Continued on next page