TAPE-DAT (Tape Consistency)
Issue 4 May 2002
10-1643 555-233-123
Table 10-607. TEST #421 Tape Data Consistency Check Test
Error
Code
Te s t
Result Description/Recommendation
0 ABORT The test timed out without completing. This error can occur
when the system is heavily loaded and the test is not allocated
sufficient time to run.
1. Rerun the test when the system is less busy and is not
running standby maintenance.
1029
1030
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
2023
2024
2025
2051
ABORT Refer to the STBY-SPE (Standby SPE) Maintenance
documentation for a description of these error codes.
9005 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
35498 ABORT Difficulty was encountered trying to send information between
the SPEs.
35512 ABORT The Standby SPE cannot be put into maintenance mode.
1. Resolve all DUPINT (Duplication Interface Circuit Pack),
SHDW-LNK (Memory Shadowing Link), SHDW-CIR
(Common Shadow Circuit), and STBY-SPE (Standby
SPE) alarms.
2. Retry the command.
35514 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
Continued on next page