Maintenance Object Repair Procedures
555-233-123
10-1656 Issue 4 May 2002
Notes:
a. The circuit pack stopped functioning or is physically removed from the
system.
NOTE:
This alarm logs approximately 11 minutes after removing the circuit
pack and/or the SAKI Sanity Test (#53) fails.
If the circuit pack is not in the system, insert a circuit pack in the same slot
as the error indicates. See note (g).
b. Transient communication problems between the switch and this circuit
pack. Execute the test board PCSS command and refer to the repair
procedures for the Control Channel Loop Around Test (#52).
1025 (e) 4363 NPE/NCE Audit Test
(#50)
None ON
1291 (f) 4359 Clear Error Counters
(#270)
MINOR ON
1294 (g) 46088
to
46096
SAKI Sanity Test (#53) MINOR ON See (h)
1537 (h) 46082 MINOR ON
1793 (i) 46080 MINOR ON
1794 (i) 46094 MINOR ON
1795 (i) 46085 MINOR ON
2305 (j) 46104 None ON
2306 (i) 46081 None ON
3330 (j) 46083 MINOR OFF
3586 (k) MINOR OFF
3840(l) 4096
to
4101
3842 (m) 46095
3843 (n) 46097
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
Table 10-608. TBRI-BD Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page