Maintenance Object Repair Procedures
555-233-123
10-1684 Issue 4 May 2002
Slip Query Test (#1244)
This test is nondestructive.
Slips occur when the transmitter and receiver are not running at precisely the
same clock rate. The Slip Alarm Inquiry Test polls the total number of slips that
have occurred on a link.
When the TN2185 circuit pack detects a slip condition, maintenance software
initiates the Slip Alarm Inquiry Test to query the slip counters on the TN2185
circuit pack and total the slip counts in the maintenance software.
1187 ABORT The circuit pack or port may have been busied out by a
technician.
1. Look in the Error Log for Error Type 18 (busied out ) for
TBRI-BD or TBRI-PT.
a. If this error type is present for TBRI-PT, then release
the port with the release port PCSSpp command and
run the test again.
b. If the error is present for both TBRI-BD and TBRI-PT,
then release the circuit pack with the release board
PPCSS command and run the test again.
NOTE:
When you release the circuit pack, you release all
ports associated with it. If certain ports still need to be
busied out, use the release port PCSSpp command to
busy them out.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5
times.
2012 ABORT Internal system error
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS The switch has successfully sent a Status Enquiry message.
Table 10-619. TEST #1243 Layer 3 Query Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page

Table of Contents