TBRI-TRK (TN2185 ISDN Trunk-Side BRI)
Issue 4 May 2002
10-1691 555-233-123
ISDN Test Call Test (#258)
This test performs a far-end loop around to a far-end switch over an ISDN trunk.
The trunk’s service state must be in-service, maint-NE, or out-of-service/NE, and
no call can be active on the trunk.
Table 10-623. TEST #257 Call State Audit Test
Error
Code
Te s t
Result Description/Recommendation
1018 ABORT The test is disabled.
1. Enable the test by entering y in the
Maintenance
Tests?
field on page 2 of the change trunk-group
form.
1019 ABORT An audit is already in progress.
1. Wait two minutes and try again.
1113 ABORT The signaling link has failed, so the system cannot send any
messages on behalf of this trunk.
1. Check the results of Test #1251 (Signaling Link State
Check).
1114 ABORT The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1116 ABORT The trunk is in an out-of-service ISDN service state.
1. A call cannot be present if the trunk is in an ISDN
out-of-service state, so a call state audit would be
inappropriate. No action necessary. (Use the status trunk
command.)
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS The audit passed successfully.
Continued on next page