Maintenance Object Repair Procedures
555-233-123
10-1714 Issue 4 May 2002
For a system with a TN768,TN780 or TN2182 Tone-Clock Circuit Pack:
Notes:
a. Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation
for descriptions of these tests.
b. Refer to TONE-BD (Tone-Clock Circuit Pack) documentation for a
description of this test.
c. Refer to TONE-PT (Tone Generator) documentation for descriptions of
these tests.
d. This test only runs on the Standby Tone-Clock circuit pack in a Port
Network with more than one Tone-Clock circuit pack (High or Critical
Reliability Option). The circuit pack must be a TN780 code with firmware
revision 2 or above or be a TN2182.
e. Test #149 is not run on a TN2182.
Table 10-629. System Technician-Demanded Tests: TDM-BUS
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive, ND = Non-destructive
SAKI Reset Test (#53) (a) X D
Clock Health Test (#46) (b) X X ND
Control Channel Loop Around Test (#52) (a) X X ND
Tone Generator Crosstalk Test (#90) (c) X ND
Tone Generator Transmission Test (#40) (c) X X ND
Tone Generator Audit/Update Test (#41) (c) X X ND
TDM Bus Clock Circuit Status Inquiry Test (#148) X X ND
TDM Bus Clock Slip Inquiry Test (#149) (e) X X ND
TDM Bus Clock PPM Inquiry Test (#150) X X ND
TDM Clock Board Type (#574) X ND
TDM Bus Clock Parameter Update Test (#151) X X ND
Standby Reference Health Check Test (#651) (d) X ND
Continued on next page