Maintenance Object Repair Procedures
555-233-123
10-1746 Issue 4 May 2002
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some of the tone detectors may be out of service.
Issue the list measurements tone-receiver command to
display basic information about the system’s tone receivers.
1. Look for TTR-LEV errors in the error log. If present, refer
to the TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the error log. If present, refer
to the TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute
intervals for a maximum of 5 times.
1004 ABORT The port was seized by a user for a valid call. Use display
port UUCSSpp to determine the trunk group/member number
of the port. Use status trunk to determine the service state of
the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait
until the port is idle before retesting.
1. If the port status is idle, retry the command at 1-minute
intervals for a maximum of 5 times.
1018 ABORT Test disabled via administration. This only applies to analog
stations.
1. To enable test, set the Test field on the station
administration screen for the particular analog station
being tested to "y." Use change station <extension>.
1020 ABORT The test did not run due to a previously existing error on the
specific port or because of a more general circuit pack error.
1. Examine the Error Log for existing errors against this port
or circuit pack, and attempt to diagnose the previously
existing error.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-643. TEST #7 Conference Circuit Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page