Maintenance Object Repair Procedures
555-233-123
10-1750 Issue 4 May 2002
FAIL Internal System Error.
1. Retry the command at 1-minute intervals a maximum of 5
times.
PASS Trunk translation has been updated successfully. The current
trunk states kept in the DS1 Interface circuit pack and switch
software are consistent. If the trunk is busied out, the test
does not run, but it does return PASS. To verify that the trunk
is in-service:
1. Enter status trunk command to verify that the trunk is
in-service. If the trunk is in-service, no further action is
necessary. If the trunk is out-of-service, continue to Step
2.
2. Enter release trunk command to put trunk back into
in-service.
3. Retry the test command.
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is
inserted, an incorrect board is inserted, or an insane board is
inserted.
1. Check to ensure that the board translations are correct.
Use list config , and resolve any problems that are
found.
2. If the board was found to be correctly inserted in step 1,
issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should
re-establish the linkage between the internal ID and the
port. If this is not the case, check to see that there is a
valid board inserted.
Table 10-644. TEST #36 Audit and Update Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page