Maintenance Object Repair Procedures
555-233-123
10-1752 Issue 4 May 2002
1004 ABORT Far end is seizing the trunk while the test is ongoing. A glare
situation is detected. Current test is designed to be aborted.
Use display port UUCSSpp to determine the trunk
group/member number of the port. Use status trunk to
determine the service state of the port. If the service state
indicates that the port is in use, then the port is unavailable for
certain tests. You must wait until the port is idle before
retesting.
1. If the port status is idle, retry the command at 1-minute
intervals for a maximum of 5 times.
1005 ABORT Test failed due to incompatible configuration administered in
trunk group form.
1. Verify the following fields on the trunk group administration
screen:
a. Is trunk direction incoming only?
b. Is trunk outgoing type either automatic or
immediate-start?
c. Is trunk the 24th port of the DS1 Interface circuit pack
while common control channel signaling is specified?
2. If the trunk has been administered using the above
information, then this test should abort.
1018 ABORT The test was disabled via translation. You may want to
determine why the test has been disabled before you enable it.
1. Verify that the ’Maintenance Test’ field on the ’Trunk
Administration’ screen is set to ’n.’ To enable the test,
change the trunk administration and enter ’y’ into the
’Maintenance Test’ field.
2. Repeat the test.
1020 ABORT The test did not run due to an already existing error on the
specific port or due to a more general circuit pack error.
1. Examine the error log for existing errors against this port or
the circuit pack and attempt to diagnose the already
existing error.
2. Retry the test.