EasyManua.ls Logo

Avaya Definity SI - Page 254

Avaya Definity SI
2968 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-4 Issue 4 May 2002
Output
The following example shows the output from the busyout board 1c07
command, and assumes that board in cabinet 1, carrier c, slot 7 is an analog
board with three administered ports. The responses display on a test-by-test basis
with one line of data for each test result.
Field descriptions
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance
Name
The name of maintenance object
Alt. Name
Alternate way to identify maintenance objects.
If the Object is The field contains
station extension
trunk xxx/yyy (xxx = trunk group, yyy = member)
private CO line P/xxx (xxx = private CO line group number)
Result
Test result: Pass, Abort, or Fail
Error Code
Numeric code explaining why the release failed or aborted. Refer to
the detailed list of the codes by test number for each MO.
busyout board 01C07 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C07 ANL-BD PASS
01C0702 ANL-LINE PASS
01C0701 ANL-LINE 51001 PASS
01C0703 ANL-LINE PASS
Command successfully completed

Table of Contents