TIE-TRK (Tie Trunk)
Issue 4 May 2002
10-1765 555-233-123
129 ABORT The 404-Hz reflective loop around test aborted. Response to
the test request was not received within the allowable time
period.
131 The 1004-Hz reflective loop around test aborted. Response to
the test request was not received within the allowable time
period.
133 The 2804-Hz reflective loop around test aborted. Response to
the test request was not received within the allowable time
period.
1. Retry the command at 1-minute intervals for a maximum
of 5 times.
1000 ABORT System resources required to run this test are not available.
The trunk may be busy with a valid call. Use display trunk xx
to determine the trunk group/member number of the port. Use
status trunk to determine the service state of the port. If the
service state indicates that the port is in use, the port is
unavailable for certain tests. (Refer to the “Status Commands”
section in Chapter 8, ‘‘Maintenance Commands and
Trouble-Clearing Aids’’ for a full description of all possible
states.) You must wait until the port is idle before retesting.
1. If the port status is active, but the port is not in use (no
calls), check the Error Log for Error Type 1025 (see Error
Log table for a description of this error and required
actions). The port may be locked up.
2. If the port status is idle, retry the command at 1-minute
intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS Maintenance to diagnose any active TDM-BUS
errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
Table 10-648. TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page