TIE-TRK (Tie Trunk)
Issue 4 May 2002
10-1769 555-233-123
Audit Update Test (#36)
This test sends updates of the Tie Trunk port translation for all ports on the circuit
pack that have been translated. The update is non-disruptive and guards against
possible corruption of translation data contained on the board. No response
message is expected from the circuit pack once it receives translation updates.
The port translation data for non-TN439 and non-TN497 circuit packs includes the
following: Immediate, automatic, wink-start or delay dial trunk, rotary or DTMF
senderization in or out, disconnect timing from 10 to 2550ms in 10ms increments,
and DMTF time slot. (Continuous-seize-ack is also included for the TN2140
[G3iV2-386] circuit pack.) The port translation data for the TN439 circuit pack
includes the following: Immediate or wink-start trunk, rotary or DTMF
senderization in or out, disconnect timing from 10 to 2550ms in 10ms increments,
and DMTF time slot.
Table 10-649. TEST #36 Audit Update Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at one minute intervals a maximum of
5 times.
1006 ABORT (TN439 and TN497 circuit packs only.) The port is in the
out-of-service state. The test cannot be run.
1. Retry the command once the port is in service.
2100 ABORT Could not allocate the necessary system resources to run the
test. This could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5
times.
FAIL Internal System Error.
1. Retry the command at one minute intervals a maximum of
5 times.
Continued on next page