TONE-BD (Tone-Clock Circuit Pack)
Issue 4 May 2002
10-1799 555-233-123
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the following tables when
inspecting errors in the system. By clearing error codes associated with the SAKI
Sanity Test, for example, you may also clear errors generated from other tests in
the testing sequence.
Use the list configuration control command to find the Tone-Clock Circuit Pack
Code of the system. Look for the Short and Long Test Sequences according to the
Tone-Clock Circuit Pack Code.
For a system with a TN756 Tone-Clock Circuit Pack:
a. Refer to XXX-BD (Common Port Circuit Pack) documentation for
descriptions of these tests.
b. Refer to TONE-PT (Tone Generator) documentation for descriptions of
these tests.
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive; ND = Nondestructive
SAKI Sanity Test (#53) (a) X D
Clock Health Inquiry Test (#46) X X ND
Control Channel Loop Around Test (#52) (a) X X ND
Tone Detection Verification Test (#42) (b) X X ND
Tone Detection Audit/Update Test (#43) (b) X X ND
Tone Generator Crosstalk Test (#90) (b) X ND
Tone Generator Transmission Test (#40) (b) X X ND
Tone Generator Audit/Update (#41) (b) X X ND