TSC-ADM (Administered Temporary Signaling
Connections)
Issue 4 May 2002
10-1825 555-233-123
2000 ABORT The Administered TSC is not responding to a TSC heartbeat
inquiry.
1. Retry the test tsc-administered command at 1-minute
intervals a maximum of three times.
2. If the problem continues to fail, obtain the status of the
D-channel or D-channel pair associated with the
ADMTSC via status sig-group <group> . If the
D-channel is INS (that is, in-service) and the status of the
ADMTSC appears to be active, disable and enable the
ADMTSC through administration. NOTE: To disable the
ADMTSC, display the (administration) Signaling Group
Form via change sig-group <group> where <group>
refers to the number of the signaling group under which
the suspect TSC is administered. Change the "Enable"
field to "n." To enable the ADMTSC, change the "Enable"
field to "y."
3. Reissue the test tsc-administered command.
4. If the test fails, check the ADMTSC node on the other
side of the network to verify that the ADM TSC is indeed
active.
2012 ABORT Internal System Error.
1. Reissue the test tsc-administered command at
1-minute intervals a maximum of 5 times.
1 FAIL The Administered TSC is not active (far-end).
1. Reissue the test tsc-administered command.
2. Verify that the Administered TSC node on the other side
of the network is active.
3. Disable and enable the Administered TSC.
4. Retry the test tsc-administered command.
2 FAIL Facility IE (Information Element) reject.
1. Check all other nodes in the network, and make sure
Administered TSC is active.
PASS The Administered TSC responded to a heartbeat.
Table 10-663. TEST #604 TSC Heartbeat Inquiry Test
Error
Code
Te s t
Result Description/Recommendation
Continued on next page