TTR-LEV (TTR Level)
Issue 4 May 2002
10-1829 555-233-123
Hardware Error Log Entries and Test to Clear
Val ues
!
WARNING:
The Alarm is upgraded to MAJOR if the Base Tone Generator is set to 12
(France).
Notes:
a. Error code 1 does not indicate a current error condition. It indicates that the
number of DTMR ports in service was below the administered threshold,
but is now equal to or greater than the threshold. These errors are typically
generated during boot time or other transitional states when the ports are
being brought into service.
b. The total number of DTMR ports currently in service is below the
administered threshold. To clear the alarm, refer to the repair procedure
described above.
c. Error code 3 does not indicate a current error condition. It indicates that the
number of GPTD ports in service was below the administered threshold,
but is now equal to or greater than the threshold. These errors are typically
generated during boot time or other transitional states when the ports are
being brought into service.
d. The total number of GPTD ports currently in service is below the
administered threshold. To clear the alarm, refer to the repair procedure
describe above.
TTR Level Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
1 (a) 1 None
2 (b) 2 WARNING (See
the WARNING
message below)
OFF
3 (c) 3 None
4 (d) 4 WARNING OFF
5 (e) 5 None
6 (f) 6 WARNING OFF
7 (g) 7 MAJOR OFF
8 (h) 8 MINOR OFF
9 (i) 9 MINOR OFF