Maintenance Object Repair Procedures
555-233-123
10-1846 Issue 4 May 2002
Notes:
a. Error Type 1 indicates that the circuit pack has totally stopped
functioning or is not fully administered. The alarm is logged about 15
minutes after the circuit pack has been removed or 11-minutes after the
SAKI Test (#53) fails.
To be fully administered, a UDS1 circuit pack must meet all three of the
following conditions:
1. Have an entry in the circuit plan using the change circuit pack
command
2. Be administered using the add ds1 UUCSS command
3. Be physically inserted into the correct slot
If the circuit pack has an entry in the circuit plan and either of the other two
conditions are not met, a MINOR alarm is logged. To resolve the error
either:
1. Make sure that all conditions for administration are met and that a
functioning UDS1 circuit pack is inserted in the correct slot, or
3843(ab) 46081
3900(ac) Any CPE Loopback Jack
Test (#1212)
3901(ad) Any Far CSU Loopback
Test (#1213)
3902(ae) Any One-Way Span Test
(#1214)
3999(af) Any None
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
2 If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the
circuit pack, then a warning alarm is raised. The alarm is raised after the circuit pack has been missing
for a period of 15 minutes. Warning alarms are also raised against any ports administered on the
circuit pack.
3 Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
4 Major alarms on this MO may be downgraded to minor or warning alarms based on values set in the
set options command.
Table 10-667. DS1 Interface Circuit Pack Maintenance Error Log Entries Continued
Error
Type
Aux
Data Associated Test Alarm Level
On/
Off
Board Test to Clear Value
Continued on next page