UDS1-BD (UDS1 Interface Circuit Pack)
Issue 4 May 2002
10-1855 555-233-123
Table 10-668. System Technician-Demanded Tests
Order of Investigation
Short
Te s t
Sequence
Long Test
Sequence
Reset
Board
Sequence
test
ds1-loop
D/
ND
1
1 D = Destructive; ND = Nondestructive
Echo Cancellation Test (#1420) X D
NPE Connection Audit Test (#50) X ND
Control Channel Loop Test (#52) X ND
Loss of Signal Alarm Inquiry Test (#138) X X ND
Blue Alarm Inquiry Test (#139) X X ND
Red Alarm Inquiry Test (#140) X X ND
Yellow Alarm Inquiry Test (#141) X X ND
Major Alarm Inquiry Test (#142) X X ND
Minor Alarm Inquiry Test (#143) X X ND
Slip Alarm Inquiry Test (#144) X X ND
Misframe Alarm Inquiry Test (#145) X X ND
Translation Update Test (#146) X X ND
ICSU Status LEDs Test (#1227) X X ND
SAKI Sanity Test (#53) X D
Internal Looparound Test (#135) X D
DS1/CSU Loopback Tests:
DS1 Board Loopback Test (#1209)
CSU Equipment Loopback Test (#1210)
CSU Repeater Loopback Test (#1211)
X
X
X
D
D
D
CPE Loopback Jack Test (#1212) X D
Far CSU Loopback Test (#1213) X D
One-Way Span Test (#1214) X D
Inject Single Bit Error (#1215) X D
End Loopback/Span Test (#1216) X D